Burner as a professional product, Career related staff will go into professional training before use, and provide remote
After the expiration of the burner warranty, will it affect the follow-up service?No impact, after the warranty period of burner products, Zhibo carries out lifelong paid maintenance service for burner
What is the telephone number for Career burner pre-sale and after-sales consultation?Career burner pre-sale and after-sales hotline:太阳集团8722c 13702340609.
What are the "three guarantees" promised by Career Burner?Career burner according to the national standard commitment, Career products to implement three guarantees of service, t
How long is the warranty period for Career burner products?The warranty period of Career burner is within one year after the delivery of the equipment, free maintenance within the
Possible causes include oil supply pipeline blockage, oil pump not pumping, oil supply pipeline vacuum leakage, etc. Unl
The flame of the burner is unstable when it runs, and it often reignites automatically after extinguishing the fire.When the fuel supply is insufficient, with the strength and weakness of the flame, the burner is often accompanied by wh
Burner ignition is normal but exhaust smoke color is abnormal.The diesel injected into the burner is mixed and burned at the same time. When the air supply volume is appropriate, the
The flame of the burner is unstable when it runs, and it often reignites automatically after extinguishing the fire. Burner ignition is normal but exhaust smoke color is abnormal.The typical reason for this phenomenon is the smudged flame sensor of burner accessories. Flame sensor is a photosensiti
After the power is switched on, the motor of the burner begins to rotate. After the blowing program is started, the nozzle does not spray oil mist. Later, the fault red light lights up and the burner stops working.1. Low fuel tank: Send fuel to the tank. 2. Air in the tubing: discharge the air in the pipe according to the exhaust pr
After the main power switch is switched on, the red light of the controller is not bright, and the burner has no working signs. How to solve the problem?Cause analysis: There may be no power supply to the burner.Solution: Check the power fuse, wire, power switch, etc., the
What does the chain protection test cover?1. Air pressure switch2. Low pressure switch3. High pressure switch4. Flameout protection5. Protection of every point of
What is the operating process of cold state debugging of gas burner?1. Debug fan positive and negative rotation and flue gas reflux fan positive and negative rotation (point motion)2. Test
What is the operating process of hot state debugging of fuel burner?1. Turn on the air switch of the fan2.2. Check whether the short-circuit signal switch during simulation debugging is re
What preparations should be made for the burner before debugging?1. Check whether the installation of the burner, the installation of the flue gas butterfly valve, the installation of t